In the Linux kernel, the following vulnerability has been resolved: drm/xe/display: fix oops in suspend/shutdown without display The xe driver keeps track of whether to probe display, and whether display hardware is there, using xe->info.probe_display. It gets set to false if there's no display after intel_display_device_probe(). However, the display may also be disabled via fuses, detected at a later time in intel_display_device_info_runtime_init(). In this case, the xe driver does for_each_intel_crtc() on uninitialized mode config in xe_display_flush_cleanup_work(), leading to a NULL pointer dereference, and generally calls display code with display info cleared. Check for intel_display_device_present() after intel_display_device_info_runtime_init(), and reset xe->info.probe_display as necessary. Also do unset_display_features() for completeness, although display runtime init has already done that. This will need to be unified across all cases later. Move intel_display_device_info_runtime_init() call slightly earlier, similar to i915, to avoid a bunch of unnecessary setup for no display cases. Note #1: The xe driver has no business doing low level display plumbing like for_each_intel_crtc() to begin with. It all needs to happen in display code. Note #2: The actual bug is present already in commit 44e694958b95 ("drm/xe/display: Implement display support"), but the oops was likely introduced later at commit ddf6492e0e50 ("drm/xe/display: Make display suspend/resume work on discrete"). (cherry picked from commit 7c3eb9f47533220888a67266448185fd0775d4da)
4.10.0-14.16~16.04.14.10.0-19.21~16.04.14.10.0-20.22~16.04.14.10.0-21.23~16.04.14.10.0-22.24~16.04.14.10.0-24.28~16.04.14.10.0-26.30~16.04.14.11.0-13.19~16.04.14.11.0-14.20~16.04.14.13.0-16.19~16.04.3+13 more5.0.0-1021.24~18.04.15.0.0-1022.25~18.04.15.0.0-1023.26~18.04.15.0.0-1024.27~18.04.15.0.0-1025.285.0.0-1027.305.3.0-1016.17~18.04.15.3.0-1017.18~18.04.15.3.0-1019.21~18.04.15.3.0-1023.25~18.04.15.3.0-1028.30~18.04.15.3.0-1030.32~18.04.15.3.0-1032.34~18.04.25.3.0-1033.355.3.0-1034.365.3.0-1035.374.15.0-1002.24.15.0-1003.34.15.0-1004.44.15.0-1008.84.15.0-1009.94.15.0-1012.124.15.0-1013.134.15.0-1014.144.15.0-1018.184.15.0-1019.19+34 more5.3.0-1007.8~18.04.15.3.0-1008.9~18.04.15.3.0-1009.10~18.04.15.3.0-1010.11~18.04.15.3.0-1012.13~18.04.15.3.0-1013.14~18.04.15.3.0-1016.17~18.04.15.3.0-1018.19~18.04.15.3.0-1019.20~18.04.15.3.0-1020.21~18.04.1+6 more4.18.0-1006.6~18.04.14.18.0-1007.7~18.04.14.18.0-1008.8~18.04.15.0.0-1012.12~18.04.24.15.0-1001.14.15.0-1003.34.15.0-1005.54.15.0-1006.64.15.0-1008.84.15.0-1009.94.15.0-1010.104.15.0-1014.144.15.0-1015.154.15.0-1017.18+28 more5.3.0-1008.9~18.04.15.3.0-1009.10~18.04.15.3.0-1010.11~18.04.15.3.0-1012.13~18.04.15.3.0-1014.15~18.04.15.3.0-1016.17~18.04.15.3.0-1017.18~18.04.15.3.0-1018.19~18.04.15.3.0-1020.22~18.04.15.3.0-1026.28~18.04.1+3 more4.15.0-1030.324.15.0-1032.344.15.0-1033.354.15.0-1034.364.15.0-1036.384.15.0-1037.394.15.0-1040.424.15.0-1041.434.15.0-1042.444.15.0-1044.46+23 more5.4.0-1025.25~18.04.15.4.0-1027.28~18.04.15.4.0-1029.31~18.04.15.4.0-1030.32~18.04.15.4.0-1032.34~18.04.15.4.0-1033.35~18.04.15.4.0-1035.37~18.04.15.4.0-1036.38~18.04.15.4.0-1037.39~18.04.15.4.0-1039.41~18.04.1+27 moreExploitability
AV:LAC:LPR:LUI:NScope
S:UImpact
C:NI:NA:HCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H