FlowIntel contains an authorization flaw in its duplicate alert ingestion logic. When a duplicate alert is received and its content is updated, the ownership and visibility scope fields (owner user and owner organization) were not refreshed to reflect the connector's current scope. As a result, an alert that was originally created under a broader visibility scope retained that broader scope even after the connector's scope was narrowed or changed.
This means that users or organizations that should no longer have visibility into a given alert could continue to access it, because the stale ownership fields were never updated during the duplicate-update path. The issue affected all duplicate updates, including those involving alerts in terminal review states and those recovered from uniqueness conflicts.
Security impact:
Affected version: <4.1.0.
Exploitability
AV:NAC:LAT:NPR:LUI:NVulnerable System
VC:LVI:NVA:NSubsequent System
SC:NSI:NSA:N5.3/CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:NAccess Control
Other